solar.halowerk.com
Continuous load is the sum of the running watts of all appliances marked as simultaneous. The surge check adds the largest single starting surge on top of the continuous load, which is the case that trips an inverter; simultaneous starts of two motors are reported separately as a second figure. Starting factors and power factors are design rules of thumb per appliance class and are stated in the response, they are not device data.
Offering
- Provider
- solar.halowerk.com
- Method
- POST
- Offering type
- Api Endpoint
- Transport type
- http
- Category
- General Utilities
- Delivery
- Not provided
- Pricing model
- Not provided
- x402 version
- 2
Endpoint context
- URL
https://solar.halowerk.com/inverter-load-check- MIME type
- Not provided
- First seen
- 2026-10-16T01:58:26.121Z
- Last seen
- Tags
- None supplied
Payment pricing
x402 payment terms are the authoritative price for calling this endpoint.
- Payment option 1
- 0.002 USDC
Atomic price: 2000 · Network: eip155:8453 · Asset: USDC · Scheme: exact
Raw x402 terms
[
{
"scheme": "exact",
"network": "eip155:8453",
"asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
"amount": "2000",
"payTo": "0x2880EdfFF13100677Bf97A3CBdF3Bc34771C4E5E"
}
]Observed health
- Status
- Healthy
- Latest latency
- 317 ms
- Average latency
- 722 ms
- HTTP status
- 204
- Last checked
- Reachability
- 100% over 8 checks
Latency is measured to the first response headers. A reachable result does not verify response accuracy or merchant identity.
Input schema
{
"additionalProperties": false,
"properties": {
"body": {
"additionalProperties": false,
"properties": {
"battery_voltage_v": {
"description": "For the DC current figure. Without it that field stays null.",
"maximum": 1000,
"minimum": 6,
"type": "number"
},
"inverter": {
"additionalProperties": false,
"properties": {
"continuous_w": {
"maximum": 100000,
"minimum": 50,
"type": "number"
},
"efficiency": {
"default": 0.9,
"maximum": 1,
"minimum": 0.5,
"type": "number"
},
"idle_w": {
"default": 15,
"maximum": 500,
"minimum": 0,
"type": "number"
},
"surge_w": {
"description": "Peak rating. Defaults to twice the continuous rating.",
"maximum": 400000,
"minimum": 50,
"type": "number"
}
},
"required": [
"continuous_w"
],
"type": "object"
},
"loads": {
"items": {
"additionalProperties": false,
"properties": {
"name": {
"type": "string"
},
"power_factor": {
"maximum": 1,
"minimum": 0.3,
"type": "number"
},
"quantity": {
"default": 1,
"maximum": 200,
"minimum": 1,
"type": "integer"
},
"simultaneous": {
"default": true,
"description": "False if the appliance never runs together with the others.",
"type": "boolean"
},
"surge_factor": {
"maximum": 12,
"minimum": 1,
"type": "number"
},
"type": {
"description": "Appliance class: resistive, electronics, led, motor, pump, compressor, induction.",
"type": "string"
},
"watts": {
"maximum": 50000,
"minimum": 0.1,
"type": "number"
}
},
"required": [
"name",
"watts"
],
"type": "object"
},
"maxItems": 60,
"minItems": 1,
"type": "array"
}
},
"required": [
"inverter",
"loads"
],
"type": "object"
},
"bodyType": {
"enum": [
"json",
"form-data",
"text"
],
"type": "string"
},
"method": {
"enum": [
"POST",
"PUT",
"PATCH"
],
"type": "string"
},
"type": {
"const": "http",
"type": "string"
}
},
"required": [
"type",
"method",
"bodyType",
"body"
],
"type": "object"
}Output schema
{
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"input": {
"additionalProperties": false,
"properties": {
"body": {
"additionalProperties": false,
"properties": {
"battery_voltage_v": {
"description": "For the DC current figure. Without it that field stays null.",
"maximum": 1000,
"minimum": 6,
"type": "number"
},
"inverter": {
"additionalProperties": false,
"properties": {
"continuous_w": {
"maximum": 100000,
"minimum": 50,
"type": "number"
},
"efficiency": {
"default": 0.9,
"maximum": 1,
"minimum": 0.5,
"type": "number"
},
"idle_w": {
"default": 15,
"maximum": 500,
"minimum": 0,
"type": "number"
},
"surge_w": {
"description": "Peak rating. Defaults to twice the continuous rating.",
"maximum": 400000,
"minimum": 50,
"type": "number"
}
},
"required": [
"continuous_w"
],
"type": "object"
},
"loads": {
"items": {
"additionalProperties": false,
"properties": {
"name": {
"type": "string"
},
"power_factor": {
"maximum": 1,
"minimum": 0.3,
"type": "number"
},
"quantity": {
"default": 1,
"maximum": 200,
"minimum": 1,
"type": "integer"
},
"simultaneous": {
"default": true,
"description": "False if the appliance never runs together with the others.",
"type": "boolean"
},
"surge_factor": {
"maximum": 12,
"minimum": 1,
"type": "number"
},
"type": {
"description": "Appliance class: resistive, electronics, led, motor, pump, compressor, induction.",
"type": "string"
},
"watts": {
"maximum": 50000,
"minimum": 0.1,
"type": "number"
}
},
"required": [
"name",
"watts"
],
"type": "object"
},
"maxItems": 60,
"minItems": 1,
"type": "array"
}
},
"required": [
"inverter",
"loads"
],
"type": "object"
},
"bodyType": {
"enum": [
"json",
"form-data",
"text"
],
"type": "string"
},
"method": {
"enum": [
"POST",
"PUT",
"PATCH"
],
"type": "string"
},
"type": {
"const": "http",
"type": "string"
}
},
"required": [
"type",
"method",
"bodyType",
"body"
],
"type": "object"
}
},
"required": [
"input"
],
"type": "object"
}